Needled Blanket
Description
N-F-1600 alumina fiber blanket is made by laying and mechanically needle-punching polycrystalline short fibers. The binder-free construction provides a flexible, low-density insulation layer for high-temperature equipment.
CHARACTERISTICS
- Double-sided needle-punched structure
- No organic binder in the described construction
- Low heat storage and thermal conductivity
- Flexible insulation for thermal cycling
SPECIFICATION
| Property | Specification |
|---|---|
| Model | N-F-1600 |
| Classification temperature | 1600°C |
| Brochure long-term service temperature | 1500°C |
| Al₂O₃ / SiO₂ | 71–73% / 27–29% |
| Al₂O₃ + SiO₂ | >99% |
| Fiber diameter | 5–7 µm |
| Thickness (mm) | Bulk density (kg/m³) | Listed lengths (mm) | Width (mm) |
|---|---|---|---|
| 8 | 96 / 128 | 3600 / 7200 / 10000 / 12000 | 610 |
| 10 | 128 / 150 | 3600 / 7200 / 10000 / 12000 | 610 |
| 12.5 | 96 / 128 / 150 | 3600 / 7200 / 10000 / 12000 | 610 |
| 25 | 96 / 128 | 3600 / 7200 | 610 |
| 50 | 96 / 128 | 3600 / 7200 | 610 |
Areal weight by construction
| Thickness (mm) | Bulk density (kg/m³) | Areal weight (g/m²) |
|---|---|---|
| 8 | 96 | 768 |
| 8 | 128 | 1024 |
| 10 | 128 | 1280 |
| 10 | 150 | 1500 |
| 12.5 | 96 | 1200 |
| 12.5 | 128 | 1600 |
| 12.5 | 150 | 1875 |
| 25 | 96 | 2400 |
| 25 | 128 | 3200 |
| 50 | 96 | 4800 |
| 50 | 128 | 6400 |
PERFORMANCE
| Test condition | Brochure value |
|---|---|
| Thermal conductivity at 600°C | 0.064 W/(m·K) |
| At 800°C | 0.094 W/(m·K) |
| At 1000°C | 0.169 W/(m·K) |
| At 1300°C | 0.217 W/(m·K) |
| 24 h linear shrinkage at 1300°C | 0.4% |
| 24 h linear shrinkage at 1500°C | 0.9% |
| Specific heat at 1090°C | 1.315 kJ/(kg·K) |
Classification temperature is not a universal continuous operating limit. Confirm density, atmosphere, loading and test conditions for the proposed installation.
CUSTOMIZATION
The brochure identifies custom 8–12.5 mm thicknesses and densities of 96–150 kg/m³; standard thicker formats are listed above.
APPLICATION
- Kiln and furnace linings
- High-temperature gaskets
- Filtration media
- Thermal and acoustic insulation
CERTIFICATION
Specify the required technical data sheet, batch certificate of analysis and application test reports in your inquiry. Certification scope must be confirmed for the selected grade and manufacturing site; company management-system credentials do not replace product qualification.